Enterprise networks · connected ELV services

Enterprise & Campus Network Solutions

Bring WAN security, switching, Wi-Fi, business applications and ELV services into one coordinated equipment scope, with ports, power and responsibilities defined.

H3C equipment · NexPro-Link design, selection & project supply

Factory networking application environment
H3C FS6300V2-48UX2Q4C-EI — official product photograph
H3C FS6300V2-48UX2Q4C-EI · Official product source ↗

One network · explicit service boundaries

Connect the business and the building.

Define each service, its traffic, electrical load and operator. Coordinate H3C infrastructure with selected ELV endpoints and application platforms.

01

WAN & security

ISP handoffs, gateways, VPN and security policies. Size enabled inspection throughput, sessions and availability rather than relying on physical port speed.

02

Core, aggregation & access

Switch roles, fiber/copper interfaces, uplink contention, routing and recovery paths. Label every link and reserve ports for servers and failover.

03

WLAN & authentication

Country-specific radios, actual client capability, RF coverage, concurrency, roaming and controller/cloud licensing. PHY speed is not a client throughput guarantee.

04

Business servers & management

Compute, storage, DNS/DHCP, identity, monitoring, logs and backup. Confirm workloads, NICs, management access and software entitlements.

05

CCTV, voice, IPTV & access

Cameras/NVR/VMS, SIP phones, TV distribution and access services. Review sustained video, multicast, QoS, endpoint power and platform compatibility.

06

Racks, cabling & continuity

Fiber/ODF, copper termination, cabinets, PDU and UPS. Equipment depth, ventilation, PoE input loads, outage duration and earthing inform the scope.

New construction & upgrades

Choose a practical delivery path.

Use the documents already available. Detailed quantities and installation responsibilities are resolved as the design develops.

New construction

  • Coordinate equipment rooms, routes and point positions with architectural and electrical plans.
  • Compare architecture, radio coverage, capacity, power and resilience before equipment selection.
  • Issue an identified device schedule and complete BOM for phased procurement.

Existing network upgrade

  • Inventory models, configurations, measured loads and cable test results.
  • Label retained, replaced and added equipment; define temporary links and rollback.
  • Pilot one zone and test actual business/ELV services before wider migration.
  1. 01 / Define

    Drawings, endpoints, applications, existing assets and operating constraints.

  2. 02 / Engineer

    Device positions, topology, port/PoE/optical budgets and service boundaries.

  3. 03 / Specify

    Exact models, paired optics, power/fans, software and reference-tagged BOM.

  4. 04 / Supply & support

    Approved configuration, coordinated equipment, documentation and agreed acceptance support.

Exact models · defined roles

Build the equipment path.

View all 14 H3C candidates →
H3C EGT910-H-PD — official product photograph

Zone ONU with PoE+

EGT910-H-PD

Several APs, cameras or phones near a local power point.

120W total PoE output; device maximum consumption <150W.

Model, source & quote selection →
H3C WA7338-HI — official product photograph

Indoor Wi-Fi 7 AP

WA7338-HI

High demand indoor WLAN where RF design and upstream capacity justify it.

41.8W in bt/DC mode; 24.3W in at mode, per official operating conditions.

Model, source & quote selection →
H3C IEF4320-8T2P2XR-PWR-EI — official hardware drawing

Industrial zone access

IEF4320-8T2P2XR-PWR-EI

DIN-rail access for separated telemetry, surveillance or local industrial services.

60W total PoE from DC or PoE IN; full device load 80W.

Model, source & quote selection →
H3C S5130S-28P-HPWR-EI-AC — official product photograph

Copper PoE access

S5130S-28P-HPWR-EI-AC

Small or medium local PoE access with GE fiber uplinks.

370W total; official full-load examples: 24 af ports or 12 at ports.

Model, source & quote selection →
H3C S5560X-30C-EI — official product photograph

Compact campus core / aggregation

S5560X-30C-EI

Modest routed networks with a checked uplink and service port plan.

Published maximum dual AC consumption 91W for listed configuration; recalculate with expansion/optics.

Model, source & quote selection →
H3C F1000-AI-15 — official hardware drawing

Enterprise security gateway

F1000-AI-15

A candidate WAN / policy boundary, sized after enabled-service throughput review.

Hardware guide lists 48W device power consumption.

Model, source & quote selection →

Six industry reference designs

See the architecture become a purchasing scope.

Each example includes assumptions, a physical topology, logical/power notes, exact H3C candidates, calculations and a downloadable BOM. These are reference designs, not completed installation claims.

Hotel application environment
Reference design · NPL-HOT-100-R1

100-room hotel · XGS-PON reference design

A room-based network with locally powered ONUs, a separate common-area PoE branch and an explicit bandwidth plan for guest, TV and operational services.

View topology, equipment & BOM →
Commercial / Office Building application environment
Reference design · NPL-BLD-024-R1

Office building · 24-zone fiber access

A six-floor office reference with 24 point-to-point fiber links, local access power and a measurable upgrade path from 2.5GE access to selected 10GE ports.

View topology, equipment & BOM →
Factory & Warehouse application environment
Reference design · NPL-FAC-004-R1

Factory · industrial zone and office network

Separate office access, warehouse mobility and production telemetry around four industrial network zones, with explicit PoE and environmental limits.

View topology, equipment & BOM →
Public Building application environment
Reference design · NPL-GOV-002-R1

Government building · two physically separate networks

An illustrative public-service network and restricted office network with independent switches, uplinks, fiber cables and management paths.

View topology, equipment & BOM →
Education application environment
Reference design · NPL-SCH-016-R1

School campus · 16-zone multichannel Ethernet

Four building groups with passive intermediate distribution and 16 dedicated 10G terminal channels, plus an explicit plan for local terminal power.

View topology, equipment & BOM →
Retail application environment
Reference design · NPL-MAL-016-R1

Shopping mall · fiber data and remote copper power

Sixteen retail/common-area zones fed by point-to-point optical Ethernet and a separately engineered hybrid cable DC path, with a 40W output limit at each terminal.

View topology, equipment & BOM →

Hotel starting points: 20 to 500 rooms

Use the property size to open a planning conversation. Room count alone does not determine AP, camera, switch or optical port quantity.

Read the hotel sizing guide

Engineering inputs that change selection

Check the limits before the model list is approved.

Calculations use project assumptions and current manufacturer documentation. Final designs need measured routes, actual endpoint loads and agreed acceptance criteria.

DecisionWhat must be checkedWhat it changes
Ports & capacityEndpoint quantity/speed; active vs spare ports; combo exclusivity; uplink ratio; video/client bursts.Access/core model, quantity, uplink rate and expansion.
Optical pathTx/Rx wavelengths, SMF/MMF, connector/polish; fiber + connector + splice + passive loss + maintenance margin.Matched module pair/set, ODF and achievable path—not distance alone.
PON serviceOLT board/protocol, ONU model/release, split ratio, class, branch loading, multicast and registration.Shared capacity, optics and provisioning; an OLT chassis alone is insufficient.
Electrical powerPoE class per endpoint; total output; device input; cable/conversion losses; PSU failure mode; UPS runtime.PSU, adapters, hybrid conductor gauge, number of powered endpoints and backup scope.
WLANWall materials, channels, country code, concurrent clients, roaming, interference and Ethernet bottlenecks.AP type/locations, controller/cloud and AP capacity licenses.
Resilience & operationsSingle failure domains, diverse routes, recovery protocol, port use, management access, spares and support.Backup devices/links, software and tested recovery procedure.

Optical budget method: route attenuation + connector losses + splice losses + splitter/passive insertion loss + agreed margin ≤ usable optical budget of the matched transmitting/receiving class. Verify receive overload at short distances too.

Partner equipment · coordinated supply

Specified by role. Quoted as a complete scope.

NexPro-Link works with H3C, IP-COM, Fanvil, TP-Link and Huawei as technology and equipment supply partners, with wholesale and project quotations.

H3CIP-COMFanvilTP-LinkHuawei

H3C is the manufacturer of the H3C equipment shown. NexPro-Link provides selection, project supply and agreed design support. Cross-brand protocol, software, optical and power compatibility must be confirmed for the exact models. CCTV manufacturing and OEM/ODM remain a separate NexPro-Link offering.

Selection & procurement questions

Practical answers before you specify.

What is the difference between optical Ethernet and PON?

Point-to-point optical Ethernet assigns an Ethernet link to each access device. H3C multichannel Ethernet can carry separate Ethernet channels through a matched passive assembly. PON instead uses an OLT, passive splitters and registered ONUs that share a PON port. Compare usable busy-hour bandwidth, optical loss, endpoint power, management, compatibility and migration effort—not just the amount of fiber.

Is an all-optical network suitable for every building?

No single architecture fits every site. Existing certified copper, available floor rooms, route distances, local power and maintenance skills may favor conventional Ethernet. Fiber may help long routes or distributed access, but APs, ONUs and switches still need electricity. Start with the retained assets and service requirements, then compare complete equipment, cabling, power and operating costs.

Can you design a network from architectural drawings?

Yes. Drawings help establish zones, routes, equipment rooms and proposed device positions. We also need intended use, client/device counts, existing systems and required services. The first deliverable can identify assumptions and missing inputs; RF coverage, actual cable condition, optical loss and installation constraints need site verification before a final construction or purchasing release.

Can we keep some existing switches and cabling?

Often, after checking model/release support, available ports, uplink capacity, PoE budgets, fiber measurements and copper test results. A migration schedule should label each item retain, replace or add, show temporary interconnections, define the outage and rollback plan, and test voice, video, authentication and management before the next zone is moved.

How do you select H3C models for a project?

We start with device roles and exact interfaces, then check capacity, environmental conditions, power input/output and required software. The full model suffix matters: FS5500V2-24UXS6Y-EI has base 2.5GE access and licensed upgrades on selected ports, while ES4200-8P2RX-B has different PoE budgets under local and remote power. The proposed model, accessories and unresolved configuration items are listed together.

Are transceivers and licenses included in the quotation?

They are included only when expressly listed. Ask for quantity and exact SKU of both optical ends, fiber/connector type, wavelengths, rated loss/distance, PSU/fan sets and feature/AP/security licenses. Multichannel optics must be a matched generation/set; PON needs the correct OLT board, optic class and ONU interoperability. A chassis price alone is not a complete network BOM.

How are APs and access devices powered?

Use a compatible PoE copper port, local AC/DC adapter, or an approved hybrid fiber/copper power system. Glass fiber carries data only. Hybrid cables use electrical conductors alongside fiber and need voltage-drop, gauge, length and receiver checks. Calculate each PSE port limit and total switch/ONU budget, including startup, losses, reserve and the required single-supply failure condition.

Can the network carry CCTV, IPTV and IP phones?

Yes, when interfaces and service requirements are compatible. CCTV adds sustained recording traffic and storage/retention demand; IPTV may require multicast with an IGMP querier and controlled replication; phones need the supported SIP/PBX platform, power and QoS. Define VLANs, routing/ACLs, DHCP/DNS, time synchronization, peak demand and backup power, then test the actual endpoint/software combination.

Can H3C equipment work with other brands?

Standards-based Ethernet and selected optical links can interoperate when speed, wavelength, connector, fiber and configuration match. That does not guarantee proprietary management, stacking, PON ONU registration or hybrid power compatibility. Give us the exact other-brand model and firmware so the common protocol path, unsupported functions and required bench tests can be identified.

Do you provide wholesale project pricing?

NexPro-Link supplies H3C and partner-brand equipment with wholesale and project quotations. Send models and quantities if you have a BOQ, or drawings if selection is still open. The offer confirms exact configuration, regional availability, accessories, licenses, warranty/support scope, payment and delivery terms. No fixed discount, stock position or lead time is implied by these reference pages.

What information is needed for a network BOQ?

Start with the country, building use, new-build/upgrade stage, drawings or current device list, and the services to connect. Useful follow-up inputs are port/client counts, distances, fiber/copper tests, power and UPS needs, security boundaries, availability targets and preferred brands. Use the downloadable checklist and leave unknown fields blank; uncertain quantities are identified before quotation.

Are the displayed projects actual installations or reference designs?

These six projects are reference designs prepared to explain architecture, model selection and BOM structure. They are not claims of completed customer installations. Each states its assumed scale, port/power calculations and outstanding site inputs. Official H3C product photographs or hardware drawings are identified separately from application imagery, and model sources are linked beside the specifications.

Your next step

Start with the information you have.

Send a short requirement, drawings, an existing BOQ or the exact H3C models you need. We will identify the selection and supply scope.

The page, architecture and reference equipment are included automatically. Your selected quote-list quantities can be edited before sending.

Add project details, if known

One attachment up to 3 MB, or a shared-file link. Unknown engineering fields can be confirmed later.

Send a quick inquiry

A short message is enough to get started.

Contact and inquiry details
I’m interested in
Page details included with your inquiry

Request: Network design from drawings · Architecture: Enterprise / campus architecture to define

Add company details or a file (optional)

PDF, DWG, Excel, CSV, JPG, PNG or Word · up to 3 MB.

We use these details to respond to your inquiry. Privacy policy

Prefer a conversation? WhatsApp us or send an email.

Catalog Chat