Exact model
NX-TB-HY01-BR
Buried, single-direction
- Installation
- Buried
- Direction
- Single-direction
- Drive
- Hydraulic / electro-hydraulic
- Control
- Remote / wired control
- Available length
- Standard 3 m, 4 m or 6 m


A hydraulic or electro-hydraulic tyre-killer platform for controlled vehicle entrances. Four installation configurations are available with remote or wired control and standard 3 m, 4 m or 6 m length options.
One product family, exact configurations
Compare the documented installation formats on one page. Shared technical parameters are listed once below, while each quoteable model keeps its own identity and uncropped product image.

Exact model
Buried, single-direction

Exact model
Surface-mounted, single-direction

Exact model
Buried, bidirectional

Exact model
Surface-mounted, bidirectional
Product features
Source-supported characteristics for model selection and technical discussion.
Feature 01
Four exact configurations with separately bound product images
Feature 02
Buried or surface-mounted installation
Feature 03
Single-direction or bidirectional lane control
Feature 04
Remote or wired operation with 3 m, 4 m or 6 m length options
NX-TB-HY01 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| NexPro product family | NX-TB-HY01 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Quoteable configurations | NX-TB-HY01-BR, NX-TB-HY01-SF, NX-TB-HY01-DB, NX-TB-HY01-DS | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Configuration count | 4 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter scope | Published technical data applies to the documented tyre-killer family | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Drive type | Hydraulic / electro-hydraulic | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Rated voltage | 220 V | V | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Output power | 200 W | W | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Raising speed | 1 s-2 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Lowering speed | 1 s-2 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Protection rating | IP68 | IP68 | Confirm the operating environment and required protection level for the installation site. |
| Control interface | Remote / wired control | — | Confirm protocol, credential and platform compatibility before sample approval. |
| Storage environment | Protected against rain, moisture and dust | — | Confirm the operating environment and required protection level for the installation site. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Material | Q235 carbon steel | — | Verify against the approved drawing, opening direction and installation conditions. |
| Surface treatment | Multi-layer anti-corrosion coating | — | Verify against the approved drawing, opening direction and installation conditions. |
| Corrosion protection | Electrostatic powder coating | — | Verify against the approved drawing, opening direction and installation conditions. |
| Blade thickness | 10 mm-15 mm | mm | Verify against the approved drawing, opening direction and installation conditions. |
| Blade height | 150 mm | mm | Verify against the approved drawing, opening direction and installation conditions. |
| Panel thickness | 12 mm-20 mm | mm | Verify against the approved drawing, opening direction and installation conditions. |
| Published operating-cycle statement | 50 million cycles | — | Verify against the approved drawing, opening direction and installation conditions. |
| Power-failure operation | Emergency lowering during power failure | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Dynamic load rating | Published dynamic rating: container truck above 120 t | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Static load rating | 80 T | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Vehicle impact statement | Published performance statement: 10 t truck at 80 km/h stopped; project verification required | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Reflective film | Black/yellow reflective film | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Operating noise | <40 dB | dB | Confirm the current model revision in the final technical submittal before purchase order. |
| Length options | Standard 3 m, 4 m or 6 m | m | Confirm the current model revision in the final technical submittal before purchase order. |
| Control cabinet dimensions | 600 mm x 350 mm x 400 mm | mm | Verify against the approved drawing, opening direction and installation conditions. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-TB-HY01 | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | security-inspection-perimeter | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Restricted vehicle lanes, Critical facilities, Perimeter checkpoints | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model, quantity and configuration | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after technical scope review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm site dimensions, operating environment and control interfaces before order. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Series-level published data must be reconfirmed for the selected exact configuration. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Final compliance, impact, detection and range claims require approved project submittal evidence. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Application reference
Documented installation environments for layout and configuration discussion. Final civil works and interfaces are confirmed for each project.







Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEMSource-controlled answers for model selection and RFQ preparation.
Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.
They support preliminary selection. Final values are confirmed in the approved project technical submittal.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Request DatasheetSend your preferred time and discussion scope for a technical call request.
Request Call