OEM Available
NX-TB-HY01-BR Buried, single-direction tyre killer
NX-TB-HY01-BR - Buried, single-direction
NX-TB-HY01

Hydraulic Tyre Killer System

A hydraulic or electro-hydraulic tyre-killer platform for controlled vehicle entrances. Four installation configurations are available with remote or wired control and standard 3 m, 4 m or 6 m length options.

Configurations4
DriveHydraulic / electro-hydraulic
ControlRemote / wired control
Length options3 m / 4 m / 6 m
MOQConfirm by model, quantity and configuration
Lead TimeConfirm after technical scope review
FOB PortChina main ports
OEM / OptionsReview Model Scope

One product family, exact configurations

Select the Exact Model for Your RFQ

Compare the documented installation formats on one page. Shared technical parameters are listed once below, while each quoteable model keeps its own identity and uncropped product image.

4 exact models
NX-TB-HY01-BR Buried, single-direction

Exact model

NX-TB-HY01-BR

Buried, single-direction

Installation
Buried
Direction
Single-direction
Drive
Hydraulic / electro-hydraulic
Control
Remote / wired control
Available length
Standard 3 m, 4 m or 6 m
Request quote for NX-TB-HY01-BR
NX-TB-HY01-SF Surface-mounted, single-direction

Exact model

NX-TB-HY01-SF

Surface-mounted, single-direction

Installation
Surface-mounted
Direction
Single-direction
Drive
Hydraulic / electro-hydraulic
Control
Remote / wired control
Available length
Standard 3 m, 4 m or 6 m
Request quote for NX-TB-HY01-SF
NX-TB-HY01-DB Buried, bidirectional

Exact model

NX-TB-HY01-DB

Buried, bidirectional

Installation
Buried
Direction
Bidirectional
Drive
Hydraulic / electro-hydraulic
Control
Remote / wired control
Available length
Standard 3 m, 4 m or 6 m
Request quote for NX-TB-HY01-DB
NX-TB-HY01-DS Surface-mounted, bidirectional

Exact model

NX-TB-HY01-DS

Surface-mounted, bidirectional

Installation
Surface-mounted
Direction
Bidirectional
Drive
Hydraulic / electro-hydraulic
Control
Remote / wired control
Available length
Standard 3 m, 4 m or 6 m
Request quote for NX-TB-HY01-DS

Product features

Key Product Characteristics

Source-supported characteristics for model selection and technical discussion.

Feature 01

Four exact configurations with separately bound product images

Feature 02

Buried or surface-mounted installation

Feature 03

Single-direction or bidirectional lane control

Feature 04

Remote or wired operation with 3 m, 4 m or 6 m length options

Full Specifications

NX-TB-HY01 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.

Engineering data sheet

NX-TB-HY01 technical review record

Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.

Model / schedule code
NX-TB-HY01
Product family
security-inspection-perimeter
Typical application
Restricted vehicle lanes / Critical facilities
Technical status
Final submittal required
ParameterSpecified valueUnit / standardEngineering verification
NexPro product familyNX-TB-HY01—Confirm the current model revision in the final technical submittal before purchase order.
Quoteable configurationsNX-TB-HY01-BR, NX-TB-HY01-SF, NX-TB-HY01-DB, NX-TB-HY01-DS—Confirm the current model revision in the final technical submittal before purchase order.
Configuration count4—Confirm the current model revision in the final technical submittal before purchase order.
Parameter scopePublished technical data applies to the documented tyre-killer family—Confirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
Drive typeHydraulic / electro-hydraulic—Confirm the current model revision in the final technical submittal before purchase order.
Rated voltage220 VVConfirm input supply, polarity and backup sizing against the project electrical design.
Output power200 WWConfirm input supply, polarity and backup sizing against the project electrical design.
Raising speed1 s-2 s—Confirm the current model revision in the final technical submittal before purchase order.
Lowering speed1 s-2 s—Confirm the current model revision in the final technical submittal before purchase order.
Protection ratingIP68IP68Confirm the operating environment and required protection level for the installation site.
Control interfaceRemote / wired control—Confirm protocol, credential and platform compatibility before sample approval.
Storage environmentProtected against rain, moisture and dust—Confirm the operating environment and required protection level for the installation site.
ParameterSpecified valueUnit / standardEngineering verification
MaterialQ235 carbon steel—Verify against the approved drawing, opening direction and installation conditions.
Surface treatmentMulti-layer anti-corrosion coating—Verify against the approved drawing, opening direction and installation conditions.
Corrosion protectionElectrostatic powder coating—Verify against the approved drawing, opening direction and installation conditions.
Blade thickness10 mm-15 mmmmVerify against the approved drawing, opening direction and installation conditions.
Blade height150 mmmmVerify against the approved drawing, opening direction and installation conditions.
Panel thickness12 mm-20 mmmmVerify against the approved drawing, opening direction and installation conditions.
Published operating-cycle statement50 million cycles—Verify against the approved drawing, opening direction and installation conditions.
Power-failure operationEmergency lowering during power failure—Confirm input supply, polarity and backup sizing against the project electrical design.
ParameterSpecified valueUnit / standardEngineering verification
Dynamic load ratingPublished dynamic rating: container truck above 120 t—Confirm the current model revision in the final technical submittal before purchase order.
Static load rating80 T—Confirm the current model revision in the final technical submittal before purchase order.
Vehicle impact statementPublished performance statement: 10 t truck at 80 km/h stopped; project verification required—Confirm the current model revision in the final technical submittal before purchase order.
Reflective filmBlack/yellow reflective film—Confirm the current model revision in the final technical submittal before purchase order.
Operating noise<40 dBdBConfirm the current model revision in the final technical submittal before purchase order.
Length optionsStandard 3 m, 4 m or 6 mmConfirm the current model revision in the final technical submittal before purchase order.
Control cabinet dimensions600 mm x 350 mm x 400 mmmmVerify against the approved drawing, opening direction and installation conditions.
ParameterSpecified valueUnit / standardEngineering verification
ModelNX-TB-HY01SKUUse the exact model code on drawings, BOQ, quotation and purchase order.
Product familysecurity-inspection-perimeterCategoryConfirm the selected family matches the complete system architecture.
Typical applicationsRestricted vehicle lanes, Critical facilities, Perimeter checkpointsApplicationValidate suitability against the actual site workflow and environment.
MOQConfirm by model, quantity and configurationOrderConfirm by final model mix, finish and customization scope.
Lead timeConfirm after technical scope reviewScheduleReconfirm after sample approval and before project delivery planning.
FOB portChina main portsIncotermConfirm Incoterm, destination and consolidation plan in the quotation.
OEM / ODMAvailableSupplyConfirm logo, finish, packaging, labels, manuals and firmware scope where applicable.
RFQ confirmationConfirm site dimensions, operating environment and control interfaces before order.ProjectInclude this item in the technical clarification record.
RFQ confirmationSeries-level published data must be reconfirmed for the selected exact configuration.ProjectInclude this item in the technical clarification record.
RFQ confirmationFinal compliance, impact, detection and range claims require approved project submittal evidence.ProjectInclude this item in the technical clarification record.

Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.

Application reference

Reference Installations

Documented installation environments for layout and configuration discussion. Final civil works and interfaces are confirmed for each project.

7 documented views
Tyre killer reference installation 1
01Tyre killer reference installation 1
Tyre killer reference installation 2
02Tyre killer reference installation 2
Tyre killer reference installation 3
03Tyre killer reference installation 3
Tyre killer reference installation 4
04Tyre killer reference installation 4
Tyre killer reference installation 5
05Tyre killer reference installation 5
Tyre killer reference installation 6
06Tyre killer reference installation 6
Tyre killer reference installation 7
07Tyre killer reference installation 7

Technical Confirmation & Project Supply

Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.

Controlled Source Record

Model / SKU
NX-TB-HY01
Image evidence
4 bound source images
Technical data
Source values retained; final submittal required
Request Product Documents

RFQ Technical Inputs

  • Confirm site dimensions, operating environment and control interfaces before order.
  • Series-level published data must be reconfirmed for the selected exact configuration.
  • Final compliance, impact, detection and range claims require approved project submittal evidence.

Quotation Handoff

Quantity basis
Confirm by model, quantity and configuration
Schedule
Confirm after technical scope review
Shipping term
China main ports
Send Technical RFQ

Related Products in This Series

Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.

Engineering Buyer FAQ

Source-controlled answers for model selection and RFQ preparation.

Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.

They support preliminary selection. Final values are confirmed in the approved project technical submittal.

Ready to Start Your Project?

Get a Project Supply Quotation for NX-TB-HY01

Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.

Model-Matched Project Supply
Model-Level Documents
FOB China Main Ports
Catalog Chat