Feature 01
Exact-model configuration: Wall-mounted configuration


A passive micro-vibration inspection system for detecting heartbeat-related vibration in stationary vehicles. Wireless sensor status, alarm output and control-centre connectivity support checkpoint inspection workflows.
Selection options
Open another same-series model to compare its exact image and specifications.
lufei-20260316-p04-wireless-micro-vibration-life-detector-cabinet
Cabinet Wireless Micro-Vibration Life Detection System
lufei-20260316-p04-wireless-micro-vibration-life-detector-wall
Wall-Mounted Wireless Micro-Vibration Life Detection System
Product features
Source-supported characteristics for model selection and technical discussion.
Feature 01
Exact-model configuration: Wall-mounted configuration
Feature 02
Passive micro-vibration sensing of heartbeat-related vehicle vibration
Feature 03
Published inspection time from 15 to 25 seconds
Feature 04
Published wireless sensor range of at least 220 m
Feature 05
Software, warning-lamp and audible alarm outputs
System capability
Documented detection behaviour and operator-facing status references for system evaluation.


NX-LD-MV01-WM - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| NexPro model | NX-LD-MV01-WM | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Product family | Micro-Vibration Life Detection | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Configuration | Wall-mounted configuration | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Source evidence | Supplier catalog physical page 4 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter scope | Variant-specific where explicitly separated; otherwise series-level published data | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Shortest inspection time | Within 15 seconds | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Typical inspection time | Within 25 seconds | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Detection principle | Passive micro-vibration sensing of heartbeat-related vibration | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Wireless sensor range | >=220 m, published value | m | Confirm protocol, credential and platform compatibility before sample approval. |
| Alarm outputs | Software interface, warning lamp and audible alarm | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Operating systems | Windows, Kylin and Linux | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Result export | USB media backup | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Control-centre integration | Operating and inspection data network connection supported | — | Confirm the current model revision in the final technical submittal before purchase order. |
| External outputs | External LED display and audible/visual alarm | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-LD-MV01-WM | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | security-inspection-perimeter | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Correctional facilities, Border checkpoints, Vehicle concealment inspection | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model, quantity and configuration | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after technical scope review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm site dimensions, operating environment and control interfaces before order. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Series-level published data must be reconfirmed for the selected exact configuration. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Final compliance, impact, detection and range claims require approved project submittal evidence. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEMSource-controlled answers for model selection and RFQ preparation.
Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.
They support preliminary selection. Final values are confirmed in the approved project technical submittal.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Request DatasheetSend your preferred time and discussion scope for a technical call request.
Request Call