A hydraulic roadblock platform for controlled vehicle entrances, available with standard or folding flap configurations. Published data covers lift control, mechanical construction and project-defined installation options.

ModelNX-RB-HF01-FD
Drive typeHydraulic
Rated voltage220 V/380 V
Raising speedApproximately 1.5-3.5 s
Lowering speedApproximately 1.5-3.5 s
MOQConfirm by model, quantity and configuration
Lead TimeConfirm after technical scope review
FOB PortChina main ports
OEM / OptionsReview Model Scope

Product features

Key Product Characteristics

Source-supported characteristics for model selection and technical discussion.

Feature 01

Exact-model configuration: Folding flap configuration

Feature 02

Hydraulic drive with 220 V or 380 V rated supply

Feature 03

Approximately 1.5 to 3.5 second raising and lowering

Feature 04

EPS or manual mechanical lowering during power failure

Feature 05

Remote, local, app and computer control options

Full Specifications

NX-RB-HF01-FD - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.

Engineering data sheet

NX-RB-HF01-FD technical review record

Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.

Model / schedule code
NX-RB-HF01-FD
Product family
security-inspection-perimeter
Typical application
Critical vehicle entrances / Government facilities
Technical status
Final submittal required
ParameterSpecified valueUnit / standardEngineering verification
NexPro modelNX-RB-HF01-FD—Confirm the current model revision in the final technical submittal before purchase order.
Product familyHydraulic Roadblocks—Confirm the current model revision in the final technical submittal before purchase order.
ConfigurationFolding flap configuration—Confirm the current model revision in the final technical submittal before purchase order.
Source evidenceSupplier catalog physical page 7—Confirm the current model revision in the final technical submittal before purchase order.
Parameter scopeVariant-specific where explicitly separated; otherwise series-level published data—Confirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
Drive typeHydraulic—Confirm the current model revision in the final technical submittal before purchase order.
Rated voltage220 V/380 VVConfirm input supply, polarity and backup sizing against the project electrical design.
Raising speedApproximately 1.5-3.5 s—Confirm the current model revision in the final technical submittal before purchase order.
Lowering speedApproximately 1.5-3.5 s—Confirm the current model revision in the final technical submittal before purchase order.
Power-failure operationEPS or manual mechanical lowering—Confirm input supply, polarity and backup sizing against the project electrical design.
Lift controlRemote control / local control / app / computer—Confirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
MaterialCarbon steel—Confirm the current model revision in the final technical submittal before purchase order.
ColourStandard yellow/black—Confirm the current model revision in the final technical submittal before purchase order.
Surface treatmentMulti-layer anti-corrosion coating—Confirm the current model revision in the final technical submittal before purchase order.
Protection ratingIP68IP68Confirm the operating environment and required protection level for the installation site.
Warning lightHigh-brightness LED warning light—Confirm the current model revision in the final technical submittal before purchase order.
Panel thickness16 mm-30 mmmmConfirm the current model revision in the final technical submittal before purchase order.
Blocking height300 mm-600 mmmmConfirm the current model revision in the final technical submittal before purchase order.
Tyre-spike materialCarbon steel—Confirm the current model revision in the final technical submittal before purchase order.
Operating temperature-30°C-75°C—Confirm the operating environment and required protection level for the installation site.
ParameterSpecified valueUnit / standardEngineering verification
Power4 kWkWConfirm input supply, polarity and backup sizing against the project electrical design.
Lengthstandard 3 m (dimensionscustomisable)mConfirm the current model revision in the final technical submittal before purchase order.
Dynamic load ratingPublished dynamic rating: container truck above 120 t—Confirm the current model revision in the final technical submittal before purchase order.
Static load rating80 T—Confirm the current model revision in the final technical submittal before purchase order.
Vehicle impact statementPublished performance statement: 6.8 t truck at 80 km/h stopped; project verification required—Confirm the current model revision in the final technical submittal before purchase order.
Reflective warningFlashing light and black/yellow reflective coating—Confirm the current model revision in the final technical submittal before purchase order.
Operating noise<40 dBdBConfirm the current model revision in the final technical submittal before purchase order.
Hydraulic power unitEmbedded hydraulic power unit / standard external 60 L unit—Confirm input supply, polarity and backup sizing against the project electrical design.
ParameterSpecified valueUnit / standardEngineering verification
ModelNX-RB-HF01-FDSKUUse the exact model code on drawings, BOQ, quotation and purchase order.
Product familysecurity-inspection-perimeterCategoryConfirm the selected family matches the complete system architecture.
Typical applicationsCritical vehicle entrances, Government facilities, Industrial compoundsApplicationValidate suitability against the actual site workflow and environment.
MOQConfirm by model, quantity and configurationOrderConfirm by final model mix, finish and customization scope.
Lead timeConfirm after technical scope reviewScheduleReconfirm after sample approval and before project delivery planning.
FOB portChina main portsIncotermConfirm Incoterm, destination and consolidation plan in the quotation.
OEM / ODMAvailableSupplyConfirm logo, finish, packaging, labels, manuals and firmware scope where applicable.
RFQ confirmationConfirm site dimensions, operating environment and control interfaces before order.ProjectInclude this item in the technical clarification record.
RFQ confirmationSeries-level published data must be reconfirmed for the selected exact configuration.ProjectInclude this item in the technical clarification record.
RFQ confirmationFinal compliance, impact, detection and range claims require approved project submittal evidence.ProjectInclude this item in the technical clarification record.

Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.

Application reference

Reference Installations

Documented installation environments for layout and configuration discussion. Final civil works and interfaces are confirmed for each project.

7 documented views
Hydraulic roadblock reference installation 1
01Hydraulic roadblock reference installation 1
Hydraulic roadblock reference installation 2
02Hydraulic roadblock reference installation 2
Hydraulic roadblock reference installation 3
03Hydraulic roadblock reference installation 3
Hydraulic roadblock reference installation 4
04Hydraulic roadblock reference installation 4
Hydraulic roadblock reference installation 5
05Hydraulic roadblock reference installation 5
Hydraulic roadblock reference installation 6
06Hydraulic roadblock reference installation 6
Hydraulic roadblock reference installation 7
07Hydraulic roadblock reference installation 7

Technical Confirmation & Project Supply

Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.

Controlled Source Record

Model / SKU
NX-RB-HF01-FD
Image evidence
1 bound source image
Technical data
Source values retained; final submittal required
Request Product Documents

RFQ Technical Inputs

  • Confirm site dimensions, operating environment and control interfaces before order.
  • Series-level published data must be reconfirmed for the selected exact configuration.
  • Final compliance, impact, detection and range claims require approved project submittal evidence.

Quotation Handoff

Quantity basis
Confirm by model, quantity and configuration
Schedule
Confirm after technical scope review
Shipping term
China main ports
Send Technical RFQ

Related Products in This Series

Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.

Engineering Buyer FAQ

Source-controlled answers for model selection and RFQ preparation.

Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.

They support preliminary selection. Final values are confirmed in the approved project technical submittal.

Ready to Start Your Project?

Get a Project Supply Quotation for NX-RB-HF01-FD

Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.

Model-Matched Project Supply
Model-Level Documents
FOB China Main Ports
Catalog Chat