Feature 01
Exact-model configuration: High-voltage perimeter controller


A pulsed high-voltage perimeter system with audible and visual alarm output, manual reset and adjustable operating parameters. It is intended for controlled high-security boundary applications.
Product features
Source-supported characteristics for model selection and technical discussion.
Feature 01
Exact-model configuration: High-voltage perimeter controller
Feature 02
Adjustable 6000 V to 12000 V high-voltage output
Feature 03
Audible, visual and voice alarm reporting
Feature 04
Manual alarm reset
Feature 05
Adjustable pulse and current parameters
NX-PF-HV01 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| NexPro model | NX-PF-HV01 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Product family | Perimeter Electric Fence | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Configuration | High-voltage perimeter controller | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Source evidence | Supplier catalog physical page 5 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter scope | Variant-specific where explicitly separated; otherwise series-level published data | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Input voltage | AC 180-240 V | V | Confirm input supply, polarity and backup sizing against the project electrical design. |
| High-voltage output | 6000 V-12000 V | V | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Static power consumption | ≤200 W | W | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Alarm current | 20-150 mA (adjustable) | mA | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Maximum output current | Approximately 500 mA | mA | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Pulse current | 100-1500 mA (adjustable) | mA | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Pulse duration | 0.1-1.5 s (adjustable) | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Pulse charge | 60-150 mC (adjustable) | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Alarm method | Audible/visual alarm and voice announcement | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Reset method | Manual reset | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Pulse interval | 0.3-1.0 s (adjustable) | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Enclosure protection rating | IP65 | IP65 | Confirm the operating environment and required protection level for the installation site. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-PF-HV01 | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | security-inspection-perimeter | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Correctional facilities, Military storage, High-security perimeter | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model, quantity and configuration | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after technical scope review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm site dimensions, operating environment and control interfaces before order. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Series-level published data must be reconfirmed for the selected exact configuration. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Final compliance, impact, detection and range claims require approved project submittal evidence. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEMSource-controlled answers for model selection and RFQ preparation.
Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.
They support preliminary selection. Final values are confirmed in the approved project technical submittal.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Request DatasheetSend your preferred time and discussion scope for a technical call request.
Request Call