OEM Available
NX-PF-HV01 High-Voltage Perimeter Electric Fence System - primary view
Original uncropped source image bound to NX-PF-HV01 from physical page 5.
NX-PF-HV01

High-Voltage Perimeter Electric Fence System

A pulsed high-voltage perimeter system with audible and visual alarm output, manual reset and adjustable operating parameters. It is intended for controlled high-security boundary applications.

ModelNX-PF-HV01
Input voltageAC 180-240 V
High-voltage output6000 V-12000 V
Static power consumption≤200 W
Alarm current20-150 mA (adjustable)
MOQConfirm by model, quantity and configuration
Lead TimeConfirm after technical scope review
FOB PortChina main ports
OEM / OptionsReview Model Scope

Product features

Key Product Characteristics

Source-supported characteristics for model selection and technical discussion.

Feature 01

Exact-model configuration: High-voltage perimeter controller

Feature 02

Adjustable 6000 V to 12000 V high-voltage output

Feature 03

Audible, visual and voice alarm reporting

Feature 04

Manual alarm reset

Feature 05

Adjustable pulse and current parameters

Full Specifications

NX-PF-HV01 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.

Engineering data sheet

NX-PF-HV01 technical review record

Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.

Model / schedule code
NX-PF-HV01
Product family
security-inspection-perimeter
Typical application
Correctional facilities / Military storage
Technical status
Final submittal required
ParameterSpecified valueUnit / standardEngineering verification
NexPro modelNX-PF-HV01—Confirm the current model revision in the final technical submittal before purchase order.
Product familyPerimeter Electric Fence—Confirm the current model revision in the final technical submittal before purchase order.
ConfigurationHigh-voltage perimeter controller—Confirm the current model revision in the final technical submittal before purchase order.
Source evidenceSupplier catalog physical page 5—Confirm the current model revision in the final technical submittal before purchase order.
Parameter scopeVariant-specific where explicitly separated; otherwise series-level published data—Confirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
Input voltageAC 180-240 VVConfirm input supply, polarity and backup sizing against the project electrical design.
High-voltage output6000 V-12000 VVConfirm input supply, polarity and backup sizing against the project electrical design.
Static power consumption≤200 WWConfirm input supply, polarity and backup sizing against the project electrical design.
Alarm current20-150 mA (adjustable)mAConfirm input supply, polarity and backup sizing against the project electrical design.
Maximum output currentApproximately 500 mAmAConfirm input supply, polarity and backup sizing against the project electrical design.
Pulse current100-1500 mA (adjustable)mAConfirm input supply, polarity and backup sizing against the project electrical design.
ParameterSpecified valueUnit / standardEngineering verification
Pulse duration0.1-1.5 s (adjustable)—Confirm the current model revision in the final technical submittal before purchase order.
Pulse charge60-150 mC (adjustable)—Confirm the current model revision in the final technical submittal before purchase order.
Alarm methodAudible/visual alarm and voice announcement—Confirm the current model revision in the final technical submittal before purchase order.
Reset methodManual reset—Confirm the current model revision in the final technical submittal before purchase order.
Pulse interval0.3-1.0 s (adjustable)—Confirm the current model revision in the final technical submittal before purchase order.
Enclosure protection ratingIP65IP65Confirm the operating environment and required protection level for the installation site.
ParameterSpecified valueUnit / standardEngineering verification
ModelNX-PF-HV01SKUUse the exact model code on drawings, BOQ, quotation and purchase order.
Product familysecurity-inspection-perimeterCategoryConfirm the selected family matches the complete system architecture.
Typical applicationsCorrectional facilities, Military storage, High-security perimeterApplicationValidate suitability against the actual site workflow and environment.
MOQConfirm by model, quantity and configurationOrderConfirm by final model mix, finish and customization scope.
Lead timeConfirm after technical scope reviewScheduleReconfirm after sample approval and before project delivery planning.
FOB portChina main portsIncotermConfirm Incoterm, destination and consolidation plan in the quotation.
OEM / ODMAvailableSupplyConfirm logo, finish, packaging, labels, manuals and firmware scope where applicable.
RFQ confirmationConfirm site dimensions, operating environment and control interfaces before order.ProjectInclude this item in the technical clarification record.
RFQ confirmationSeries-level published data must be reconfirmed for the selected exact configuration.ProjectInclude this item in the technical clarification record.
RFQ confirmationFinal compliance, impact, detection and range claims require approved project submittal evidence.ProjectInclude this item in the technical clarification record.

Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.

Technical Confirmation & Project Supply

Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.

Controlled Source Record

Model / SKU
NX-PF-HV01
Image evidence
3 bound source images
Technical data
Source values retained; final submittal required
Request Product Documents

RFQ Technical Inputs

  • Confirm site dimensions, operating environment and control interfaces before order.
  • Series-level published data must be reconfirmed for the selected exact configuration.
  • Final compliance, impact, detection and range claims require approved project submittal evidence.

Quotation Handoff

Quantity basis
Confirm by model, quantity and configuration
Schedule
Confirm after technical scope review
Shipping term
China main ports
Send Technical RFQ

Related Products in This Series

Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.

Engineering Buyer FAQ

Source-controlled answers for model selection and RFQ preparation.

Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.

They support preliminary selection. Final values are confirmed in the approved project technical submittal.

Ready to Start Your Project?

Get a Project Supply Quotation for NX-PF-HV01

Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.

Model-Matched Project Supply
Model-Level Documents
FOB China Main Ports
Catalog Chat