Feature 01
Exact-model configuration: Standard flap configuration


A hydraulic roadblock platform for controlled vehicle entrances, available with standard or folding flap configurations. Published data covers lift control, mechanical construction and project-defined installation options.
Selection options
Open another same-series model to compare its exact image and specifications.
Product features
Source-supported characteristics for model selection and technical discussion.
Feature 01
Exact-model configuration: Standard flap configuration
Feature 02
Hydraulic drive with 220 V or 380 V rated supply
Feature 03
Approximately 1.5 to 3.5 second raising and lowering
Feature 04
EPS or manual mechanical lowering during power failure
Feature 05
Remote, local, app and computer control options
NX-RB-HF01-ST - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| NexPro model | NX-RB-HF01-ST | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Product family | Hydraulic Roadblocks | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Configuration | Standard flap configuration | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Source evidence | Supplier catalog physical page 7 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter scope | Variant-specific where explicitly separated; otherwise series-level published data | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Drive type | Hydraulic | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Rated voltage | 220 V/380 V | V | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Raising speed | Approximately 1.5-3.5 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Lowering speed | Approximately 1.5-3.5 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Power-failure operation | EPS or manual mechanical lowering | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Lift control | Remote control / local control / app / computer | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Material | Carbon steel | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Colour | Standard yellow/black | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Surface treatment | Multi-layer anti-corrosion coating | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Protection rating | IP68 | IP68 | Confirm the operating environment and required protection level for the installation site. |
| Warning light | High-brightness LED warning light | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Panel thickness | 16 mm-30 mm | mm | Confirm the current model revision in the final technical submittal before purchase order. |
| Blocking height | 300 mm-600 mm | mm | Confirm the current model revision in the final technical submittal before purchase order. |
| Tyre-spike material | Carbon steel | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Operating temperature | -30°C-75°C | — | Confirm the operating environment and required protection level for the installation site. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Power | 4 kW | kW | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Length | standard 3 m (dimensionscustomisable) | m | Confirm the current model revision in the final technical submittal before purchase order. |
| Dynamic load rating | Published dynamic rating: container truck above 120 t | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Static load rating | 80 T | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Vehicle impact statement | Published performance statement: 6.8 t truck at 80 km/h stopped; project verification required | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Reflective warning | Flashing light and black/yellow reflective coating | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Operating noise | <40 dB | dB | Confirm the current model revision in the final technical submittal before purchase order. |
| Hydraulic power unit | Embedded hydraulic power unit / standard external 60 L unit | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-RB-HF01-ST | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | security-inspection-perimeter | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Critical vehicle entrances, Government facilities, Industrial compounds | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model, quantity and configuration | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after technical scope review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm site dimensions, operating environment and control interfaces before order. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Series-level published data must be reconfirmed for the selected exact configuration. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Final compliance, impact, detection and range claims require approved project submittal evidence. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Application reference
Documented installation environments for layout and configuration discussion. Final civil works and interfaces are confirmed for each project.







Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEMSource-controlled answers for model selection and RFQ preparation.
Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.
They support preliminary selection. Final values are confirmed in the approved project technical submittal.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Request DatasheetSend your preferred time and discussion scope for a technical call request.
Request Call