Feature 01
Exact-model configuration: Fixed scanner type B


An under-vehicle inspection system for capturing and reviewing chassis imagery at controlled checkpoints. Fixed and portable configurations support different lane and deployment requirements.
Selection options
Open another same-series model to compare its exact image and specifications.
lufei-20260316-p06-fixed-under-vehicle-scanner-a
Fixed Under-Vehicle Inspection System - Type A
lufei-20260316-p06-fixed-under-vehicle-scanner-b
Fixed Under-Vehicle Inspection System - Type B
lufei-20260316-p06-portable-under-vehicle-scanner
Portable Under-Vehicle Inspection System
Product features
Source-supported characteristics for model selection and technical discussion.
Feature 01
Exact-model configuration: Fixed scanner type B
Feature 02
Inductive-loop-triggered linear scanning
Feature 03
Published 12000 x 7500 image resolution
Feature 04
Published imaging and loading time within 1 second
Feature 05
Fixed and portable deployment formats
Inspection output
Original inspection-output examples shown in full for image-quality and workflow review.






NX-UV-FX01-B - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| NexPro model | NX-UV-FX01-B | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Product family | Under-Vehicle Inspection | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Configuration | Fixed scanner type B | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Source evidence | Supplier catalog physical page 6 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter scope | Variant-specific where explicitly separated; otherwise series-level published data | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Scanning method | Linear scan; inductive-loop trigger | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Resolution | 12000×7500 | — | Validate capacity against the final device count, retention target and system design. |
| Imaging time | ≤1 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Loading time | ≤1 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Compression resistance | 80 T | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Maximum scan rate | 18 kHz | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Scanner data cable | 100 m; custom length available | m | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Load capacity | 100 T | — | Validate capacity against the final device count, retention target and system design. |
| Scanning direction | One-way / bidirectional | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Illumination module | Sealed LED area light; published lifetime 80,000 h | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Protection rating | IP68; published for all-weather operation | IP68 | Confirm the operating environment and required protection level for the installation site. |
| Field of view | >170 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Scanner weight | 105 kg | kg | Verify against the approved drawing, opening direction and installation conditions. |
| Scanner dimensions | 1105 x 285 x 240 mm, including underground protection enclosure | mm | Verify against the approved drawing, opening direction and installation conditions. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| System power supply | 220 V | V | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Inspection width | ≤4500 mm | mm | Confirm the current model revision in the final technical submittal before purchase order. |
| Operating voltage | DC 24 V/220 V | V | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Ambient temperature | -20°C-60°C | — | Confirm the operating environment and required protection level for the installation site. |
| Magnification | >18x | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Vehicle inspection speed | 1-120KM/H | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-UV-FX01-B | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | security-inspection-perimeter | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Vehicle checkpoints, Customs inspection, Critical facilities | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model, quantity and configuration | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after technical scope review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm site dimensions, operating environment and control interfaces before order. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Series-level published data must be reconfirmed for the selected exact configuration. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Final compliance, impact, detection and range claims require approved project submittal evidence. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEMSource-controlled answers for model selection and RFQ preparation.
Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.
They support preliminary selection. Final values are confirmed in the approved project technical submittal.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Request DatasheetSend your preferred time and discussion scope for a technical call request.
Request Call