Feature 01
Exact-model configuration: Fixed integrated system


A fixed counter-UAS platform combining detection, tracking and interdiction functions. Published parameters cover detection coverage, concurrent targets, operating bands and response functions.
Selection options
Open another same-series model to compare its exact image and specifications.
Product features
Source-supported characteristics for model selection and technical discussion.
Feature 01
Exact-model configuration: Fixed integrated system
Feature 02
Detection frequency coverage from 70 MHz to 6000 MHz
Feature 03
Omnidirectional 360-degree detection coverage
Feature 04
Up to 245 simultaneous detected targets
Feature 05
Published detection range of at least 5 km, environment and aircraft dependent
NX-CU-FX01 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| NexPro model | NX-CU-FX01 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Product family | Counter-UAS Systems | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Configuration | Fixed integrated system | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Source evidence | Supplier catalog physical page 18 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter scope | Variant-specific where explicitly separated; otherwise series-level published data | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Detection frequency | 70 MHz - 6000 MHz | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Detection range | >=5 km, environment and aircraft dependent | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Detection coverage | Omnidirectional 360° | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Simultaneous detected targets | 245 simultaneous targets | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Detection response time | ≤3.0 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Priority scan bands | 2.4 GHz, 5.2 GHz and 5.8 GHz UAV signals | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Transmission bands | 800MHZ、900MHZ、1.2GHZ、1.6GHZ、2.4GHZ、5.8GHZ、5.1 GHz (customisable) | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Simultaneous tracks | >=15 simultaneous tracks | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Detection altitude | 0-1000m | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Per-channel transmit power | 50 W per channel | W | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Jamming range | >=2 km, environment and aircraft dependent | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Jamming coverage | 0°-360° | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Jamming modes | UAV drive-away / forced-landing modes, selectable | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Jamming response time | ≤5.0 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-CU-FX01 | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | security-inspection-perimeter | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Critical airspace protection, Industrial sites, Government facilities | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model, quantity and configuration | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after technical scope review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm site dimensions, operating environment and control interfaces before order. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Series-level published data must be reconfirmed for the selected exact configuration. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Final compliance, impact, detection and range claims require approved project submittal evidence. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEMSource-controlled answers for model selection and RFQ preparation.
Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.
They support preliminary selection. Final values are confirmed in the approved project technical submittal.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Request DatasheetSend your preferred time and discussion scope for a technical call request.
Request Call