Feature 01
Exact-model configuration: 5030C configuration


An X-ray baggage inspection platform for checkpoint and public-venue screening. The documented configurations provide different tunnel sizes while retaining the published imaging and generator data.
Selection options
Open another same-series model to compare its exact image and specifications.
lufei-20260316-p12-x-ray-security-scanner-5030a
X-Ray Security Inspection Scanner 5030A
lufei-20260316-p12-x-ray-security-scanner-5030c
X-Ray Security Inspection Scanner 5030C
lufei-20260316-p12-x-ray-security-scanner-6550c
X-Ray Security Inspection Scanner 6550C
Product features
Source-supported characteristics for model selection and technical discussion.
Feature 01
Exact-model configuration: 5030C configuration
Feature 02
Published conveyor load up to 200 kg when uniformly distributed
Feature 03
Published 0.0787 mm single copper-wire resolution
Feature 04
Adjustable conveyor speed from 0.22 to 0.5 m/s
Feature 05
Multi-energy 24-bit L-shaped photodiode detector
NX-XR-5030C - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| NexPro model | NX-XR-5030C | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Product family | X-Ray Security Inspection | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Configuration | 5030C configuration | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Source evidence | Supplier catalog physical page 12 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter scope | Variant-specific where explicitly separated; otherwise series-level published data | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Maximum conveyor load | 200 kg (uniformly distributed) | kg | Confirm the current model revision in the final technical submittal before purchase order. |
| System noise | <54 dB | dB | Confirm the current model revision in the final technical submittal before purchase order. |
| Wire resolution | 0.0787 mm diameter single solid copper wire | mm | Validate capacity against the final device count, retention target and system design. |
| Conveyor speed | 0.22-0.5 m/s | m | Confirm the current model revision in the final technical submittal before purchase order. |
| Film safety | Published as safe for ISO 1600 film | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Operating temperature / humidity | 0°C to +45°C / 20%-95% RH, without cooling equipment | — | Confirm the operating environment and required protection level for the installation site. |
| Storage temperature / humidity | 40°C to +60°C / 20%-95% RH (source catalog text) | — | Confirm the operating environment and required protection level for the installation site. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Steel penetration | 14 mm steel | mm | Confirm the current model revision in the final technical submittal before purchase order. |
| Tube voltage | 100--140 kV (adjustable) | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Tube current | 0.4-1.2 mA (adjustable) | mA | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Leakage dose rate | <0.09 µGy/h | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Power consumption | 1.5 kW, published value | kW | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Operating voltage | 220 VAC (±10), 50 ±3 Hz | VAC | Confirm input supply, polarity and backup sizing against the project electrical design. |
| X-ray beam angle | 80° | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Monitor | 19-inch high-resolution LCD | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Grey levels | 4096 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Beam direction | Top-down | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Image resolution | 1920 x 1080 | — | Validate capacity against the final device count, retention target and system design. |
| Cooling / duty cycle | Sealed oil cooling / 100% duty cycle | — | Confirm the current model revision in the final technical submittal before purchase order. |
| X-ray detector | L-shaped photodiode array detector, multi-energy, 24-bit depth | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-XR-5030C | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | security-inspection-perimeter | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Baggage screening, Logistics checkpoints, Public venues | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model, quantity and configuration | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after technical scope review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm site dimensions, operating environment and control interfaces before order. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Series-level published data must be reconfirmed for the selected exact configuration. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Final compliance, impact, detection and range claims require approved project submittal evidence. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEMSource-controlled answers for model selection and RFQ preparation.
Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.
They support preliminary selection. Final values are confirmed in the approved project technical submittal.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Request DatasheetSend your preferred time and discussion scope for a technical call request.
Request Call