N2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ N2XY 0.6/1 kV XLPE/PVC Power Cable main view
Main · Exact Or Series
N2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ

N2XY 0.6/1 kV XLPE/PVC Power Cable

NexPro N2XY 0.6/1 kV XLPE/PVC Power Cable is supplied as a configurable low-voltage power cable product family. Catalog models are preserved exactly as N2XY-J, N2XY-O, N2XY-JZ, N2XY-OZ. Use the source-derived tables below to select the required conductor construction, core arrangement, cross-section and dimensions.

Cable categoryLow-voltage power cable
Catalog modelN2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ
ConfigurationSelect from source table
MOQConfirm by cable type, size and length
Lead TimeConfirm after specification review
FOB PortConfirm in project quotation
OEM / OptionsConfirm Availability

Full Specifications

N2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.

Engineering data sheet

N2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ technical review record

Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.

Model / schedule code
N2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ
Product family
cables-connectivity
Typical application
Low-voltage distribution / Industrial power projects
Technical status
Final submittal required
ParameterSpecified valueUnit / standardEngineering verification
Website SKUn2xy—Confirm the current model revision in the final technical submittal before purchase order.
Catalog modelN2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ—Confirm the current model revision in the final technical submittal before purchase order.
Manufacturer modelsN2XY-J / N2XY-O / N2XY-JZ / N2XY-OZ—Confirm the current model revision in the final technical submittal before purchase order.
Cable categoryLow-voltage power cable—Confirm the current model revision in the final technical submittal before purchase order.
Publication statusPublish Ready Catalog—Confirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
Source parameterWith protective conductor: N2XY-J | Without protective conductor: N2XY-O—Confirm the current model revision in the final technical submittal before purchase order.
1With protective conductor: gn/ye | Without protective conductor: bk—Confirm the current model revision in the final technical submittal before purchase order.
2With protective conductor: - | Without protective conductor: bu, bn—Confirm the current model revision in the final technical submittal before purchase order.
3With protective conductor: gn/ye, bu, bn | Without protective conductor: bn, bk, gy—Confirm the current model revision in the final technical submittal before purchase order.
4With protective conductor: gn/ye, bn, bk, gy | Without protective conductor: bu, bn, bk, gy—Confirm the current model revision in the final technical submittal before purchase order.
5With protective conductor: gn/ye, bu, bn, bk, gy | Without protective conductor: bu, bn, bk, gy, bk—Confirm the current model revision in the final technical submittal before purchase order.
Source parameterWith protective conductor: N2XY-JZ | Without protective conductor: N2XY-OZ—Confirm the current model revision in the final technical submittal before purchase order.
>5With protective conductor: gn/ye, black cores with white numbering | Without protective conductor: black cores with white numbering—Confirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
ModelN2XY-J | N2XY-O | N2XY-JZ | N2XY-OZSKUUse the exact model code on drawings, BOQ, quotation and purchase order.
Product familycables-connectivityCategoryConfirm the selected family matches the complete system architecture.
Typical applicationsLow-voltage distribution, Industrial power projects, Fixed and buried installationsApplicationValidate suitability against the actual site workflow and environment.
MOQConfirm by cable type, size and lengthOrderConfirm by final model mix, finish and customization scope.
Lead timeConfirm after specification reviewScheduleReconfirm after sample approval and before project delivery planning.
FOB portConfirm in project quotationIncotermConfirm Incoterm, destination and consolidation plan in the quotation.
OEM / ODMStandard supplySupplyConfirm logo, finish, packaging, labels, manuals and firmware scope where applicable.
RFQ confirmationConfirm conductor material and construction, core count and cross-section.ProjectInclude this item in the technical clarification record.
RFQ confirmationConfirm voltage/model, installation method and environmental conditions.ProjectInclude this item in the technical clarification record.
RFQ confirmationConfirm required length, drum or coil packing, quantity and destination requirements.ProjectInclude this item in the technical clarification record.

Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.

Exact source matrices

Source Engineering Tables

Published multi-column technical data is preserved so engineers can compare the documented parameters, dimensions and configuration fields row by row.

1. Source Specification Table 1

8 source rows
Number of coresWith protective conductorWithout protective conductor
N2XY-JN2XY-O
1gn/yebk
2-bu, bn
3gn/ye, bu, bnbn, bk, gy
4gn/ye, bn, bk, gybu, bn, bk, gy
5gn/ye, bu, bn, bk, gybu, bn, bk, gy, bk
N2XY-JZN2XY-OZ
>5gn/ye, black cores with white numberingblack cores with white numbering

Selection note: use these source values for comparison and RFQ preparation. Final configuration, performance claims, application suitability and installation design must be approved in the project technical submittal.

Technical Confirmation & Project Supply

Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.

Controlled Source Record

Model / SKU
N2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ
Image evidence
1 bound source image
Technical data
Source values retained; final submittal required
Datasheet

N2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ — Product Datasheet

Document language: English

Series specifications

NYY + 2 models — Series Comparison

Document language: English

Request Additional Documents

RFQ Technical Inputs

  • Confirm conductor material and construction, core count and cross-section.
  • Confirm voltage/model, installation method and environmental conditions.
  • Confirm required length, drum or coil packing, quantity and destination requirements.

Quotation Handoff

Quantity basis
Confirm by cable type, size and length
Schedule
Confirm after specification review
Shipping term
Confirm in project quotation
Send Technical RFQ

Related Products in This Series

Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.

Engineering Buyer FAQ

Source-controlled answers for model selection and RFQ preparation.

Confirm the exact model, voltage rating, conductor or core configuration, cross-section, installation conditions, required length and applicable project requirements in the RFQ.

Provide the catalog model, conductor or core configuration, cross-section, required length, installation conditions, quantity and destination.

Ready to Start Your Project?

Get a Project Supply Quotation for N2XY-J | N2XY-O | N2XY-JZ | N2XY-OZ

Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.

Model-Matched Project Supply
Model-Level Documents
FOB China Main Ports
Catalog Chat