Capacity

10KVA-800KVA / 8KW-640KW

Phase

3-phase + N / 3-phase + N

Battery

External VRLA battery bank (32×12VDC)

Models

7 available

Select Model

Selected Model

3C33 10KS

10KVA / 8KW

Battery: External 32×12VDC (384VDC)

Size: 653×405×820mm

Weight: 120kg

Transfer: 0ms

Order Basis:Model-specificLead Time:Confirmed by orderWarranty:Per model and quotationShipping:Reviewed by destinationOEM:Scope confirmed by model
Models & Comparison

Series Model Comparison

Compare all models in this series. Click a row or select a model to update the entire page.

Technical Specifications

Complete Parameters — 3C33 10KS

Supplier specifications for the selected model. Confirm order-specific options before integration.

Catalog configuration shown. Battery, interface and destination-market options are confirmed with the order.

Series & Model Identification

· 6 params
Series3-Phase Low Frequency UPS 10KVA-800KVA Series
Model3C33 10KS
Configuration10KVA / 8KW
TopologyOnline Double Conversion with Isolation Transformer
Input / Output3-phase + N / 3-phase + N
Source statusWebsite source reviewed

Model configuration

· 6 params
Rated capacity10KVA / 8KW
Battery configurationExternal 32×12VDC (384VDC)
Product dimensions653×405×820mm
Net weight120kg
Transfer time0ms
EfficiencyAC: 90% / Battery: 90%

Input

· 3 params
Input voltage3×380/400/415VAC (3ph+N)
Input voltage range304–456VAC
Input frequency50Hz ±10%

Output

· 8 params
Output voltage3×380/400/415VAC (3ph+N)
Voltage regulation1%
Output power factor0.8
AC-mode frequency50/60Hz ±0.01Hz
Battery-mode frequency50/60Hz ±0.01Hz
THD (linear load)<2%
THD (non-linear load)<5%
Overload capacity≤110%: 60min; ≤125%: 10min; ≤150%: 1min; >150%: 200ms

Bypass

· 8 params
Bypass typeStatic switch
Bypass voltage3×380/400/415VAC (3ph+N)
Bypass frequency50/60Hz
Control modeMicroprocessor control
Transfer time0ms
Switch to bypassImmediate at 160% overload
Return from bypassAutomatic after alarm clearing
Maintenance bypassUninterrupted; 3×400V (3ph+N); 50/60Hz

Charging

· 4 params
Battery quantity32 × 12VDC; 29–32 adjustable
Rated battery voltage384VDC
Charging methodCC/CV
Charging voltage432VDC; based on 32 batteries

Key Features

· 10 features
  • Digital control online double conversion
  • Built-in output isolation transformer
  • Industrial-grade design for harsh conditions
  • Front maintenance design (easy access)
  • Adapts to various load conditions
  • Up to 4 units in parallel operation
  • Abundant communication interfaces
  • Microprocessor control
  • Static bypass switch with 0ms transfer
  • Overload capacity: 150% @ 1min, >150% @ 200ms

Original Specification Sheet

3-Phase Low Frequency UPS 10KVA-800KVA Specifications

Open the original table at full size

Why This Series

Key Engineering Advantages

Series features for procurement and engineering review. Confirm model-specific options with your quotation.

Digital control online double conversion

Built-in output isolation transformer

Industrial-grade design for harsh conditions

Front maintenance design (easy access)

Adapts to various load conditions

Up to 4 units in parallel operation

Abundant communication interfaces

Microprocessor control

Static bypass switch with 0ms transfer

Overload capacity: 150% @ 1min, >150% @ 200ms

Application Fit

Project Compatibility

Quick assessment for typical project environments and protected equipment.

Best For

Heavy industrial facilities, Large data centers, Manufacturing plants

Installation

Floor-standing

Battery

External VRLA battery bank (32×12VDC)

Phase

3-phase + N / 3-phase + N

Typical Protected Equipment

Application illustration
Application illustration; configuration depends on the project.

Example configuration varies by project. Contact engineering for your specific equipment list and load calculation.

Heavy industrial facilitiesLarge data centersManufacturing plantsPower grid substationsOil and gas installationsTransportation hubsDefense and military systems

Engineering Note: Equipment list shown is an example. Actual configuration depends on project requirements. Contact our team for a customized BOM.

Request Project Configuration
Procurement Assurance

Quality, Packaging & Delivery

What to expect before and after your UPS order — from factory QC to shipment arrival.

Quality & Compliance

Pre-shipment checkpoints confirmed by model
Battery checks defined in the order plan
Housing, label and connector review when applicable
Model-level checklist available on request
UPS supplier testing area
Supplier facility reference. Model-specific inspection records are available on request.

Packaging & Delivery

UPS supplier packing areaUPS finished packaging reference

Supplier packaging references. Confirm the carton, cushioning and pallet plan for your order.

Individual retail box with foam cushioning
Master carton / pallet for bulk orders
Sea freight (FCL/LCL), Air freight, Express courier

Warranty & After-Sales

1–2 year limited warranty. Remote technical support, spare parts availability, and replacement coordination for OEM-branded UPS systems.

Manufacturing & quality evidence

How the UPS Powersupply scope is prepared and reviewed

Provided source-facility photos cover chassis and component assembly, battery handling, test instruments, load-bank testing, aging review and finished packing.

Source production facility

  • Chassis and component assembly
  • Load-bank and electrical testing
  • Aging and packing areas
UPS assembly workshop with organized production workstationsAssembly
UPS assembly workshop with production lines, workstations and in-process units.
UPS production line with open chassis and assembly stationsAssembly
UPS production line showing open chassis, workstations and prepared components.
Technicians assembling UPS power components at a workstationAssembly
Power-component assembly at a dedicated production workstation.

Photos supplied for this website are presented as source-facility evidence. Facility ownership and order-specific evidence scope are confirmed during supplier review.

Configuration Detail

Battery, Runtime & Accessories

Battery configuration, runtime reference and compatible accessories for 3C33 10KS.

Battery

External 32×12VDC (384VDC)

Type: External VRLA

Voltage: 384VDC

Runtime

Runtime depends on configuration.

Request calculation for project-specific load.

Request Runtime Calculation

Accessories

Documents & Support

Downloads & OEM Support

Available documents for download, OEM customization options and additional support resources.

Documents

Datasheet

NX-UP-3P-002 — Product Datasheet

Document language: English

Series specifications

NX-UP-3P-002 — Series Specifications

Document language: English

OEM Support

Custom Logo
Product Label
Custom Packaging
Custom Manual
Plug Type Selection
Accessory Kit
Project Labeling
Firmware Customization
Send OEM Inquiry
Get Started

Ready to Order NX-UP-3P-002?

Three simple steps from inquiry to shipment. Your project, our engineering support.

How to Order

01

Send Requirements

Tell us quantity, destination, backup time, plug type and any OEM needs. Upload equipment list if available.

02

Review Quote & Confirm

Our team confirms model, battery, accessories and provides a project quotation with lead time.

03

Production & Shipment

Order confirmed → factory QC → packaging → consolidated shipment with tracking provided.

Request Quote for 3C33 10KS

Send your project details and our team will confirm the UPS model, battery configuration, accessories and delivery timeline.

Response timing confirmed after receipt · Technical review available
Catalog Chat