Product Documents
NX-SL-2017 — Product Datasheet
Document language: English
NX-SL-2017 — Series Specifications
Document language: English

A smartphone app, fingerprint, password, card, mechanical key smart door lock with zinc alloy, 304 stainless steel construction. Designed for apartment, commercial building, office access applications.
NX-SL-2017 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Sensor resistance | 4H pencil, 20cm continuous 1000 impacts without damage | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Sensor resolution | 500dp / 500dpi | — | Validate capacity against the final device count, retention target and system design. |
| Start time | < 1 second seconds | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Rejection rate | <=1% | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Fake admission rate | <=0.0001% | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Fingerprint capacity | 100 pieces | — | Validate capacity against the final device count, retention target and system design. |
| Comparison method | 1:N | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Finger usage angle | 360 degrees ° | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Fingerprint registration | Generate at once | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Fingerprint update | Automatic update | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Data retention | No loss due to power outage | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Light interference | Avoid direct sunlight | — | Confirm the operating environment and required protection level for the installation site. |
| Working temperature | -10 to 55 C °C | °C | Confirm the operating environment and required protection level for the installation site. |
| Storage temperature | -20 to 70 C °C | °C | Confirm the operating environment and required protection level for the installation site. |
| Working humidity | 10% to 90% | — | Confirm the operating environment and required protection level for the installation site. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Battery life | Open the door 11000 times | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Working voltage | DC 6V | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Power supply | Battery powered | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Low pressure alarm | 4.9V | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Backup power | Power bank or other mobile power supply | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Antistatic | Contact discharge 8KV / Air discharge 15KV | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Code capacity | 100 sets pieces | — | Validate capacity against the final device count, retention target and system design. |
| Password design | Change at will combination | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Password length | 8 digits | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-SL-2017 | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | smart-lock | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Apartment, Commercial Building, Office Access, Rental Property | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model mix and customization scope | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after sample and project requirements review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm door type in the RFQ. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Confirm lock body type in the RFQ. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Confirm finish color in the RFQ. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Confirm quantity in the RFQ. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Confirm branding requirement in the RFQ. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Confirm project country in the RFQ. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Manufacturing & quality evidence
Supplied smart-lock evidence covers product display, production line, automatic soldering, durability tests, motor detection and certificate document references.
Production and testing evidence available
Production line
Product display
SolderingPhotos supplied for this website are presented as source-facility evidence. Facility ownership and order-specific evidence scope are confirmed during supplier review.
Everything you need before RFQ: technical documents, OEM/ODM scope and B2B supply essentials.
Document language: English
Document language: English
Compare real product images and adjacent models from the same lock series before widening the project selection.
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEM
Same product familyOEMModel and category questions for system integrators, distributors and contractors preparing an RFQ.
Confirm door material, thickness, handing, existing lock-body dimensions, credential method, finish, emergency access and whether software or hotel management integration is required.
List the required card, keypad, fingerprint, Bluetooth or mobile workflow and the expected encoder, gateway or management software. Compatibility is confirmed for the selected system.
Yes. Send the equipment list, drawing or tender reference. The review can identify matching catalog models, related accessories and the model-level documents that are available for the selected scope.
List the required protocol, connector, voltage, software or system interface. Compatibility is checked against the selected model information and is recorded as a confirmation point before order approval.
Provide the target model, quantity, destination, logo position, label, manual language and packaging requirement. Available OEM scope and minimum quantity are confirmed per model in the quotation.
Commercial terms are confirmed for the exact model, quantity, destination and order stage. Use the issued quotation and order documents rather than a generic website statement.
Yes. Send the complete list and destination. Packing compatibility, carton grouping, document scope and the practical shipment method are reviewed before the order is confirmed.
Send the target market, tender clause and exact model list. Only documents that match the selected model and stated scope should be used for approval.
Need a model-specific answer? Send the product list for review.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Get DatasheetBook a video call with our project engineer for technical discussion and site survey.
Book Now