Feature 01
Exact-model configuration: Fully automatic two-stage


A security bollard range for managed vehicle access and perimeter protection. Automatic, semi-automatic, split-hydraulic, removable and fixed configurations support different civil-work and operating requirements.
Selection options
Open another same-series model to compare its exact image and specifications.
lufei-20260316-p09-automatic-two-stage-bollard
Fully Automatic Two-Stage Bollard
lufei-20260316-p09-semi-automatic-bollard
Semi-Automatic Bollard
lufei-20260316-p09-split-hydraulic-bollard
Split Hydraulic Bollard
lufei-20260316-p09-portable-removable-bollard
Portable Removable Bollard
lufei-20260316-p09-fixed-security-bollard
Fixed Security Bollard
Product features
Source-supported characteristics for model selection and technical discussion.
Feature 01
Exact-model configuration: Fully automatic two-stage
Feature 02
Series-level drive and power options for project selection
Feature 03
304 stainless steel or Q235 carbon steel construction options
Feature 04
Brushed or electrostatic surface-finish options
Feature 05
LED strip and reflective-film warning options
NX-BL-FA02 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| NexPro model | NX-BL-FA02 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Product family | Security Bollards | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Configuration | Fully automatic two-stage | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Source evidence | Supplier catalog physical page 9 | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter scope | Variant-specific where explicitly separated; otherwise series-level published data | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Drive type | Integrated hydraulic | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Rated voltage | 24 V/36 V/220 V | V | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Rated current | 1.7-15 A | A | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Operating power | 300 W-700 W | W | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Protection rating | IP68 | IP68 | Confirm the operating environment and required protection level for the installation site. |
| Raising speed | Approximately 1.5-3.5 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Lowering speed | Approximately 1.5-3.5 s | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Power-failure operation | EPS or manual mechanical lowering | — | Confirm input supply, polarity and backup sizing against the project electrical design. |
| Lift control | Remote / local / mobile app / computer | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Storage environment | Protected against rain, moisture and dust | — | Confirm the operating environment and required protection level for the installation site. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Bollard body material | 304 stainless steel | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Outer barrel material | Q235 carbon steel | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Outer-cylinder corrosion protection | Electrostatic powder coating | — | Confirm the operating environment and required protection level for the installation site. |
| Warning light | LED light strip | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Bollard height | 600 mm/1000 mm | mm | Confirm the current model revision in the final technical submittal before purchase order. |
| Bollard wall thickness | 6 mm/8 mm/10 mm/20 mm | mm | Confirm the current model revision in the final technical submittal before purchase order. |
| Reflective warning | 3M diamond-grade reflective film | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Bollard surface finish | Brushed surface finish | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Dynamic load rating | 120 T | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Static load rating | 80 T | — | Confirm the current model revision in the final technical submittal before purchase order. |
| Operating temperature | -30°C-75°C | — | Confirm the operating environment and required protection level for the installation site. |
| Operating noise | <40 dB | dB | Confirm the current model revision in the final technical submittal before purchase order. |
| Parameter | Specified value | Unit / standard | Engineering verification |
|---|---|---|---|
| Model | NX-BL-FA02 | SKU | Use the exact model code on drawings, BOQ, quotation and purchase order. |
| Product family | security-inspection-perimeter | Category | Confirm the selected family matches the complete system architecture. |
| Typical applications | Restricted vehicle access, Government facilities, Industrial sites | Application | Validate suitability against the actual site workflow and environment. |
| MOQ | Confirm by model, quantity and configuration | Order | Confirm by final model mix, finish and customization scope. |
| Lead time | Confirm after technical scope review | Schedule | Reconfirm after sample approval and before project delivery planning. |
| FOB port | China main ports | Incoterm | Confirm Incoterm, destination and consolidation plan in the quotation. |
| OEM / ODM | Available | Supply | Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable. |
| RFQ confirmation | Confirm site dimensions, operating environment and control interfaces before order. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Series-level published data must be reconfirmed for the selected exact configuration. | Project | Include this item in the technical clarification record. |
| RFQ confirmation | Final compliance, impact, detection and range claims require approved project submittal evidence. | Project | Include this item in the technical clarification record. |
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEM
Source catalog modelOEMSource-controlled answers for model selection and RFQ preparation.
Provide the exact model, quantity, site layout, power, interfaces, environmental conditions and destination.
They support preliminary selection. Final values are confirmed in the approved project technical submittal.
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.
Send your model list, quantity and destination for a reviewed quotation.
Start RFQFull technical specs, dimensions and available model-level documents for tender prep.
Request DatasheetSend your preferred time and discussion scope for a technical call request.
Request Call