PV Solar Cable Photovoltaic Solar Cable main view
Main · Exact Or Series

Source product views, construction details and diagrams are kept together as product evidence, not separate SKUs.

PV Solar Cable

Photovoltaic Solar Cable

NexPro Photovoltaic Solar Cable is supplied as a configurable photovoltaic cable product family. Catalog models are preserved exactly as PV Solar Cable. Use the source-derived tables below to select the required conductor construction, core arrangement, cross-section and dimensions.

Cable categoryPhotovoltaic cable
Catalog modelPV Solar Cable
ConfigurationSelect from source table
MOQConfirm by cable type, size and length
Lead TimeConfirm after specification review
FOB PortConfirm in project quotation
OEM/ODMContact Us

Full Specifications

PV Solar Cable - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.

Engineering data sheet

PV Solar Cable technical review record

Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.

Model / schedule code
PV Solar Cable
Product family
cables-connectivity
Typical application
Solar and utility projects / Outdoor distribution
Technical status
Final submittal required
ParameterSpecified valueUnit / standardEngineering verification
Website SKUsolar-cableConfirm the current model revision in the final technical submittal before purchase order.
Catalog modelPV Solar CableConfirm the current model revision in the final technical submittal before purchase order.
Manufacturer modelsPV Solar CableConfirm the current model revision in the final technical submittal before purchase order.
Cable categoryPhotovoltaic cableConfirm the current model revision in the final technical submittal before purchase order.
Publication statusPublish Ready CatalogConfirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
1.5Monofilament diameter mm / number of pieces: 0.25/30 | conductor outer diameter mm: 1.6 | Insulation thickness mm: 0.5 | Sheath thickness mm: 0.5 | Finished outer diameter mm: 3.6-4.0 | Approximate weight /km/kg: 32.33mmConfirm the current model revision in the final technical submittal before purchase order.
2.5Monofilament diameter mm / number of pieces: 0.25/49 | conductor outer diameter mm: 2.1 | Insulation thickness mm: 0.5 | Sheath thickness mm: 0.5 | Finished outer diameter mm: 4.1-4.4 | Approximate weight /km/kg: 36.82mmConfirm the current model revision in the final technical submittal before purchase order.
4Monofilament diameter mm / number of pieces: 0.30/56 | conductor outer diameter mm: 2.6 | Insulation thickness mm: 0.7 | Sheath thickness mm: 0.7 | Finished outer diameter mm: 5.4-5.7 | Approximate weight /km/kg: 67.89mmConfirm the current model revision in the final technical submittal before purchase order.
6Monofilament diameter mm / number of pieces: 0.30/84 | conductor outer diameter mm: 3.2 | Insulation thickness mm: 0.7 | Sheath thickness mm: 0.7 | Finished outer diameter mm: 6.5-6.9 | Approximate weight /km/kg: 75.44mmConfirm the current model revision in the final technical submittal before purchase order.
10Monofilament diameter mm / number of pieces: 0.40/80 | conductor outer diameter mm: 4.1 | Insulation thickness mm: 0.8 | Sheath thickness mm: 0.7 | Finished outer diameter mm: 7.1-7.5 | Approximate weight /km/kg: 95.64mmConfirm the current model revision in the final technical submittal before purchase order.
16Monofilament diameter mm / number of pieces: 0.40/126 | conductor outer diameter mm: 5.2 | Insulation thickness mm: 0.8 | Sheath thickness mm: 0.7 | Finished outer diameter mm: 8.2-8.7 | Approximate weight /km/kg: 110.46mmConfirm the current model revision in the final technical submittal before purchase order.
25Monofilament diameter mm / number of pieces: 0.40/196 | conductor outer diameter mm: 6.5 | Insulation thickness mm: 1 | Sheath thickness mm: 0.9 | Finished outer diameter mm: 10.3-10.7 | Approximate weight /km/kg: 175.75mmConfirm the current model revision in the final technical submittal before purchase order.
35Monofilament diameter mm / number of pieces: 0.40/276 | conductor outer diameter mm: 7.7 | Insulation thickness mm: 1 | Sheath thickness mm: 0.9 | Finished outer diameter mm: 11.5-12.5 | Approximate weight /km/kg: 196.22mmConfirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
ModelPV Solar CableSKUUse the exact model code on drawings, BOQ, quotation and purchase order.
Product familycables-connectivityCategoryConfirm the selected family matches the complete system architecture.
Typical applicationsSolar and utility projects, Outdoor distribution, Project-specific installationsApplicationValidate suitability against the actual site workflow and environment.
MOQConfirm by cable type, size and lengthOrderConfirm by final model mix, finish and customization scope.
Lead timeConfirm after specification reviewScheduleReconfirm after sample approval and before project delivery planning.
FOB portConfirm in project quotationIncotermConfirm Incoterm, destination and consolidation plan in the quotation.
OEM / ODMStandard supplySupplyConfirm logo, finish, packaging, labels, manuals and firmware scope where applicable.
RFQ confirmationConfirm conductor material and construction, core count and cross-section.ProjectInclude this item in the technical clarification record.
RFQ confirmationConfirm voltage/model, installation method and environmental conditions.ProjectInclude this item in the technical clarification record.
RFQ confirmationConfirm required length, drum or coil packing, quantity and destination requirements.ProjectInclude this item in the technical clarification record.

Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.

Exact source matrices

Cable Construction & Size Tables

Multi-column source tables are preserved without flattening so engineers can compare the published conductor, construction, dimension and weight fields row by row.

1. Source Specification Table 1

8 source rows
Cross-sectional area mm²Monofilament diameter mm / number of piecesconductor outer diameter mmInsulation thickness mmSheath thickness mmFinished outer diameter mmApproximate weight /km/kg
1.50.25/301.60.50.53.6-4.032.33
2.50.25/492.10.50.54.1-4.436.82
40.30/562.60.70.75.4-5.767.89
60.30/843.20.70.76.5-6.975.44
100.40/804.10.80.77.1-7.595.64
160.40/1265.20.80.78.2-8.7110.46
250.40/1966.510.910.3-10.7175.75
350.40/2767.710.911.5-12.5196.22

Selection note: use these source values for comparison and RFQ preparation. Final cable sizing, voltage/application suitability and installation design must be approved by the responsible project engineer.

Technical Confirmation & Project Supply

Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.

Controlled Source Record

Model / SKU
PV Solar Cable
Image evidence
3 bound source images
Technical data
Source values retained; final submittal required
Datasheet

PV Solar Cable — Product Datasheet

Document language: English

Series specifications

PV Solar Cable — Series Specifications

Document language: English

Request Additional Documents

RFQ Technical Inputs

  • Confirm conductor material and construction, core count and cross-section.
  • Confirm voltage/model, installation method and environmental conditions.
  • Confirm required length, drum or coil packing, quantity and destination requirements.

Quotation Handoff

Quantity basis
Confirm by cable type, size and length
Schedule
Confirm after specification review
Shipping term
Confirm in project quotation
Send Technical RFQ

Related Products in This Series

Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.

Engineering Buyer FAQ

Source-controlled answers for model selection and RFQ preparation.

Confirm the exact model, voltage rating, conductor or core configuration, cross-section, installation conditions, required length and applicable project requirements in the RFQ.

Provide the catalog model, conductor or core configuration, cross-section, required length, installation conditions, quantity and destination.

Ready to Start Your Project?

Request a Model-Level Quotation for PV Solar Cable

Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.

CCTV Manufacturing & ELV Supply
Model-Level Documents
FOB China Main Ports
Catalog Chat