NHXH E90 NHXH E90 Halogen-Free Fire-Resistant Cable main view
Main · Exact Or Series
NHXH E90

NHXH E90 Halogen-Free Fire-Resistant Cable

NexPro NHXH E90 Halogen-Free Fire-Resistant Cable is supplied as a configurable fire-resistant safety cable product family. Catalog models are preserved exactly as NHXH E90. Use the source-derived tables below to select the required conductor construction, core arrangement, cross-section and dimensions.

Cable categoryFire-resistant safety cable
Catalog modelNHXH E90
ConfigurationSelect from source table
MOQConfirm by cable type, size and length
Lead TimeConfirm after specification review
FOB PortConfirm in project quotation
OEM/ODMContact Us

Full Specifications

NHXH E90 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.

Engineering data sheet

NHXH E90 technical review record

Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.

Model / schedule code
NHXH E90
Product family
cables-connectivity
Typical application
Public buildings / Emergency circuits
Technical status
Final submittal required
ParameterSpecified valueUnit / standardEngineering verification
Website SKUnhxh-e90Confirm the current model revision in the final technical submittal before purchase order.
Catalog modelNHXH E90Confirm the current model revision in the final technical submittal before purchase order.
Manufacturer modelsNHXH E90Confirm the current model revision in the final technical submittal before purchase order.
Cable categoryFire-resistant safety cableConfirm the current model revision in the final technical submittal before purchase order.
Publication statusPublish Ready CatalogConfirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
Test voltageColumn 2: | [V]: [V]_{AC} | 600 / 1000 Volt: 4000Confirm input supply, polarity and backup sizing against the project electrical design.
Temperature rangeColumn 2: in motion | [V]: | 600 / 1000 Volt: -5°C till +90°CConfirm the operating environment and required protection level for the installation site.
Operating temperatureColumn 2: short circuit | [V]: °C | 600 / 1000 Volt: 250°CConfirm the operating environment and required protection level for the installation site.
Short circuit timeColumn 2: max. | [V]: [sec] | 600 / 1000 Volt: 5Confirm the current model revision in the final technical submittal before purchase order.
Bending radiusColumn 2: single core style | [V]: x diameter | 600 / 1000 Volt: 15Confirm the current model revision in the final technical submittal before purchase order.
multi core styleColumn 2: x diameter | [V]: 12 | 600 / 1000 Volt: —Confirm the current model revision in the final technical submittal before purchase order.
FlammabilityColumn 2: standard | [V]: | 600 / 1000 Volt: EN 50266-2-4IEC 60332-3 Kat.CConfirm the current model revision in the final technical submittal before purchase order.
ParameterSpecified valueUnit / standardEngineering verification
ModelNHXH E90SKUUse the exact model code on drawings, BOQ, quotation and purchase order.
Product familycables-connectivityCategoryConfirm the selected family matches the complete system architecture.
Typical applicationsPublic buildings, Emergency circuits, Low-smoke installation projectsApplicationValidate suitability against the actual site workflow and environment.
MOQConfirm by cable type, size and lengthOrderConfirm by final model mix, finish and customization scope.
Lead timeConfirm after specification reviewScheduleReconfirm after sample approval and before project delivery planning.
FOB portConfirm in project quotationIncotermConfirm Incoterm, destination and consolidation plan in the quotation.
OEM / ODMStandard supplySupplyConfirm logo, finish, packaging, labels, manuals and firmware scope where applicable.
RFQ confirmationConfirm conductor material and construction, core count and cross-section.ProjectInclude this item in the technical clarification record.
RFQ confirmationConfirm voltage/model, installation method and environmental conditions.ProjectInclude this item in the technical clarification record.
RFQ confirmationConfirm required length, drum or coil packing, quantity and destination requirements.ProjectInclude this item in the technical clarification record.

Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.

Exact source matrices

Cable Construction & Size Tables

Multi-column source tables are preserved without flattening so engineers can compare the published conductor, construction, dimension and weight fields row by row.

1. Source Specification Table 1

7 source rows
Nominal voltage Uo/UColumn 2[V]600 / 1000 Volt
Test voltage[V]_{AC}4000
Temperature rangein motion-5°C till +90°C
Operating temperatureshort circuit°C250
Short circuit timemax.[sec]5
Bending radiussingle core stylex diameter15
multi core stylex diameter12
FlammabilitystandardEN 50266-2-4IEC 60332-3 Kat.C

2. Source Specification Table 2

7 source rows
Number of cores and nominal cross section mm^2Copper figure kg/kmOverall diameter appr.mmCalorific potential kWh/mWeight appr. kg/km
1 x 16 RM16010,50,42250
1 x 25 RM25012,50,53355
1 x 35 RM35013,50,60460
1 x 50 RM50015,00,69596
1 x 70 RM70016,50,83810
1 x 95 RM95019,01,061.100
1 x 120 RM1.20020,51,151.350

Selection note: use these source values for comparison and RFQ preparation. Final cable sizing, voltage/application suitability and installation design must be approved by the responsible project engineer.

Technical Confirmation & Project Supply

Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.

Controlled Source Record

Model / SKU
NHXH E90
Image evidence
1 bound source image
Technical data
Source values retained; final submittal required
Datasheet

NHXH E90 — Product Datasheet

Document language: English

Series specifications

NHXH E90 — Series Specifications

Document language: English

Request Additional Documents

RFQ Technical Inputs

  • Confirm conductor material and construction, core count and cross-section.
  • Confirm voltage/model, installation method and environmental conditions.
  • Confirm required length, drum or coil packing, quantity and destination requirements.

Quotation Handoff

Quantity basis
Confirm by cable type, size and length
Schedule
Confirm after specification review
Shipping term
Confirm in project quotation
Send Technical RFQ

Related Products in This Series

Compare source-bound product images and adjacent configurations from the same documented series before widening the selection.

Engineering Buyer FAQ

Source-controlled answers for model selection and RFQ preparation.

Confirm the exact model, voltage rating, conductor or core configuration, cross-section, installation conditions, required length and applicable project requirements in the RFQ.

Provide the catalog model, conductor or core configuration, cross-section, required length, installation conditions, quantity and destination.

Ready to Start Your Project?

Request a Model-Level Quotation for NHXH E90

Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.

CCTV Manufacturing & ELV Supply
Model-Level Documents
FOB China Main Ports
Catalog Chat