NexPro NHXH E90 Halogen-Free Fire-Resistant Cable is supplied as a configurable fire-resistant safety cable product family. Catalog models are preserved exactly as NHXH E90. Use the source-derived tables below to select the required conductor construction, core arrangement, cross-section and dimensions.
NHXH E90 - structured technical parameters for engineering evaluation, RFQ clarification and tender documentation.
Engineering data sheet
NHXH E90 technical review record
Source specifications are retained as published. Verification notes identify what an engineer should confirm against drawings, system architecture and the final quotation before purchase order.
Confirm the current model revision in the final technical submittal before purchase order.
Catalog model
NHXH E90
—
Confirm the current model revision in the final technical submittal before purchase order.
Manufacturer models
NHXH E90
—
Confirm the current model revision in the final technical submittal before purchase order.
Cable category
Fire-resistant safety cable
—
Confirm the current model revision in the final technical submittal before purchase order.
Publication status
Publish Ready Catalog
—
Confirm the current model revision in the final technical submittal before purchase order.
Parameter
Specified value
Unit / standard
Engineering verification
Test voltage
Column 2: | [V]: [V]_{AC} | 600 / 1000 Volt: 4000
—
Confirm input supply, polarity and backup sizing against the project electrical design.
Temperature range
Column 2: in motion | [V]: | 600 / 1000 Volt: -5°C till +90°C
—
Confirm the operating environment and required protection level for the installation site.
Operating temperature
Column 2: short circuit | [V]: °C | 600 / 1000 Volt: 250
°C
Confirm the operating environment and required protection level for the installation site.
Short circuit time
Column 2: max. | [V]: [sec] | 600 / 1000 Volt: 5
—
Confirm the current model revision in the final technical submittal before purchase order.
Bending radius
Column 2: single core style | [V]: x diameter | 600 / 1000 Volt: 15
—
Confirm the current model revision in the final technical submittal before purchase order.
multi core style
Column 2: x diameter | [V]: 12 | 600 / 1000 Volt: —
—
Confirm the current model revision in the final technical submittal before purchase order.
Flammability
Column 2: standard | [V]: | 600 / 1000 Volt: EN 50266-2-4IEC 60332-3 Kat.C
—
Confirm the current model revision in the final technical submittal before purchase order.
Parameter
Specified value
Unit / standard
Engineering verification
Model
NHXH E90
SKU
Use the exact model code on drawings, BOQ, quotation and purchase order.
Product family
cables-connectivity
Category
Confirm the selected family matches the complete system architecture.
Typical applications
Public buildings, Emergency circuits, Low-smoke installation projects
Application
Validate suitability against the actual site workflow and environment.
MOQ
Confirm by cable type, size and length
Order
Confirm by final model mix, finish and customization scope.
Lead time
Confirm after specification review
Schedule
Reconfirm after sample approval and before project delivery planning.
FOB port
Confirm in project quotation
Incoterm
Confirm Incoterm, destination and consolidation plan in the quotation.
OEM / ODM
Standard supply
Supply
Confirm logo, finish, packaging, labels, manuals and firmware scope where applicable.
RFQ confirmation
Confirm conductor material and construction, core count and cross-section.
Project
Include this item in the technical clarification record.
RFQ confirmation
Confirm voltage/model, installation method and environmental conditions.
Project
Include this item in the technical clarification record.
RFQ confirmation
Confirm required length, drum or coil packing, quantity and destination requirements.
Project
Include this item in the technical clarification record.
Engineering note: Website data supports preliminary selection and RFQ preparation. Final voltage, interfaces, drawings, dimensions, environmental rating, accessories and firmware revision must be confirmed in the approved technical submittal.
Exact source matrices
Cable Construction & Size Tables
Multi-column source tables are preserved without flattening so engineers can compare the published conductor, construction, dimension and weight fields row by row.
1. Source Specification Table 1
7 source rows
Nominal voltage Uo/U
Column 2
[V]
600 / 1000 Volt
Test voltage
[V]_{AC}
4000
Temperature range
in motion
-5°C till +90°C
Operating temperature
short circuit
°C
250
Short circuit time
max.
[sec]
5
Bending radius
single core style
x diameter
15
multi core style
x diameter
12
—
Flammability
standard
EN 50266-2-4IEC 60332-3 Kat.C
2. Source Specification Table 2
7 source rows
Number of cores and nominal cross section mm^2
Copper figure kg/km
Overall diameter appr.mm
Calorific potential kWh/m
Weight appr. kg/km
1 x 16 RM
160
10,5
0,42
250
1 x 25 RM
250
12,5
0,53
355
1 x 35 RM
350
13,5
0,60
460
1 x 50 RM
500
15,0
0,69
596
1 x 70 RM
700
16,5
0,83
810
1 x 95 RM
950
19,0
1,06
1.100
1 x 120 RM
1.200
20,5
1,15
1.350
Selection note: use these source values for comparison and RFQ preparation. Final cable sizing, voltage/application suitability and installation design must be approved by the responsible project engineer.
Technical Confirmation & Project Supply
Move from the website record to a controlled technical clarification, exact configuration and commercial quotation without assuming unconfirmed certifications or performance data.
Source-controlled answers for model selection and RFQ preparation.
Confirm the exact model, voltage rating, conductor or core configuration, cross-section, installation conditions, required length and applicable project requirements in the RFQ.
Provide the catalog model, conductor or core configuration, cross-section, required length, installation conditions, quantity and destination.
Ready to Start Your Project?
Request a Model-Level Quotation for NHXH E90
Send your project requirements or BOM list. The team reviews the selected model, quantity, destination and customization scope, then confirms quotation timing.