← Back to Project SupplyUPS Power Solution

Data Center & Server Room Power Protection

Enterprise-grade online double conversion for mission-critical IT infrastructure

Solution Overview

The NexPro Data Center & Server Room Power Protection solution delivers enterprise-grade online double conversion UPS systems designed for the demanding requirements of modern IT infrastructure. With zero transfer time, pure sine wave output, and advanced monitoring capabilities, our UPS systems ensure continuous, clean power for servers, storage arrays, networking equipment, and other critical loads.

This comprehensive solution spans our high frequency online UPS family — from 1KVA compact tower units to 30KVA mid-power systems — along with rack-mountable models for structured cabling environments. All systems feature true online double conversion topology, microprocessor-controlled operation, wide input voltage range, and optional SNMP network management for remote monitoring and alerting. Choose from standard VRLA battery configurations or upgrade to LiFePO4 lithium battery models for longer cycle life, lighter weight, and reduced maintenance. For integrators and contractors, we provide complete system documentation, load calculation support, and full OEM/ODM customization.

Buyer Benefits
  • Zero transfer time online double conversion — no interruption during power failure
  • Complete rack-level integration — UPS, batteries, and SNMP monitoring from one factory
  • Lithium battery option — longer lifespan, lighter weight, lower TCO vs. VRLA
  • project-supply engineering support — load calculation and system design assistance
  • Full OEM/ODM — voltage, frequency, communication interfaces customized to your project

Visual project reference

See the rack load, UPS and battery layers

A server-room application scene and real rack equipment make power, installation and runtime discussions concrete.

Conceptual data-center rack environment protected by UPS powerApplication reference

Server-room load context

Conceptual application reference; actual rack load, redundancy and runtime follow the approved equipment schedule.

View details
NX-UP-RM-001 rack-mounted online UPSProduct reference

Rack-mounted online UPS

Current rack UPS reference for reviewing cabinet space, power rating, topology and communication options.

View details
IFR 48V rack-mounted LiFePO4 battery productProduct reference

Rack battery option

Battery reference for projects that require a separate runtime and communication review alongside the UPS.

View details

Application scenes are visual references. Final models, quantities and interfaces follow the approved project information.

Typical Configurations

Pre-designed configurations for common scenarios within this solution.

Small Server Room

2-4 servers, network switch, firewall

Online double conversion tower or rack UPS for entry-level server rooms

UPS Model

NX-UP-HF-001 (SP3K: 3KVA/2700W) or NX-UP-RM-001 (C3KR(S))

Runtime: 15-30 minutes

Medium Server Room

5-10 servers, SAN storage, core switch

10KVA online UPS with SNMP monitoring for managed server environments

UPS Model

NX-UP-HF-001 (SP10K: 10KVA/9000W)

Runtime: 10-20 minutes with external battery option

Data Center Rack

Full 42U rack with servers and storage

Mid-power UPS with single/three-phase input flexibility for data center racks

UPS Model

NX-UP-HF-003 (3C20K(S): 20KVA/18KW)

Runtime: 10-15 minutes with external battery bank